Allows simple configuration with WebCal software and requires no more target calibration, this FLOWLINE EchoPod® noncontact ultrasonic level sensor is a general-purpose ultrasonic level switch, controller and transmitter that provides a loop powered 4-20 mA output and 4 SPST 60 VA relays. Model has 4-20 mA output that can be used to provide the proportional level of liquid in a tank or vessel. Sensor can be used to control multiple combinations of pumps, valves, and/or alarms. The signal can be connected to most devices that accept a loop powered 4-20 mA signal or relay output, such as a PLC, SCADA, DCS, display, or controller.

Technical Specs

  • Item Noncontact Ultrasonic Level Sensor
  • Classification General Purpose
  • Range 18 ft
  • Accuracy +/-0.2% of Range
  • Resolution 0.079 in
  • Dead Band 8 in
  • Beam Width 3 in
  • Configuration WebCal
  • Input Voltage 24V DC (loop)
  • Output 4 to 20mA and (4) SPST Relays
  • Temp. Range 20 Degrees to 140 Degrees F
  • Max. Pressure 30 psi
  • Enclosure Rating Type 6P
  • Enclosure Material Polycarbonate
  • Material PVDF
  • Gasket Material Viton
  • Mounting 2 in NPT
  • Display None
  • Standards CE, cFMus, RoHS
  • Overall Length 3.1 in
  • Width 3.1
  • Height 6.5 in

Allows simple configuration with WebCal software and requires no more target calibration, this FLOWLINE EchoPod® noncontact ultrasonic level sensor is a general-purpose ultrasonic level switch, controller and transmitter that provides a loop powered 4-20 mA output and 4 SPST 60 VA relays. Model has 4-20 mA output that can be used to provide the proportional level of liquid in a tank or vessel. Sensor can be used to control multiple combinations of pumps, valves, and/or alarms. The signal can be connected to most devices that accept a loop powered 4-20 mA signal or relay output, such as a PLC, SCADA, DCS, display, or controller.