Navigation Menu New

Access My Account, Order History, Lists and more here.

Main product photo
Roll over image to zoom.

COLUMBUS ELECTRIC Hazardous Location Line Volt Mechanical Tstat: 40° to 110°F, Aluminum, Adj

Item 
6GVX9
Mfr. Model 
HLT-2-G

Product Details

Catalog Page
2898
Brand
COLUMBUS ELECTRIC
Application
Heat or Cool
Bulb Diameter
3/8 in
Bulb Length
4-3/4 in
Capillary Length
5-1/4 in
Defrost Termination
40° to 110°F
Differential Type
Adjustable
Enclosure Material
Aluminum
Enclosure NEMA Rating
NEMA 7
Maximum Control Temperature
110 °F
Minimum Control Temperature
40 °F
Number of Cooling Stages
1
Number of Heating Stages
1
Overall Depth
4-1/2 in
Overall Height
5-5/8 in
Overall Width
6-3/8 in
Switch Action
Open/Close on Rise
Switch Type
DPDT
Temperature Differential
2° to 4°F
Temperature Scale
Fahrenheit/Celsius
Thermostat Type
Hazardous Location Single-Stage Controls
Voltage
24 to 277V AC
Changeover Type
Manual
Compatible System Type
All FEP Heaters
Contact Rating
24 to 277V AC
Contact Rating Resistive @ 120V
22 A
Contact Rating Resistive @ 240V
22 A
Contact Rating Resistive @ 277V
22 A
Contact Type
Snap Action
Control Type
Screwdriver
Enclosure Color
Gray
Full Load Amps @ 120V AC
13.8 A
Full Load Amps @ 240V AC
10 A
Hazardous Location Class
1C/1D/2E/2F/2G
Inductive Amps @ 120V
13.8 A
Inductive Amps @ 208V
11 A
Inductive Amps @ 240V
10 A
Number of Poles
2
Number of Switches
2
Pilot Duty Rating
24 VA @ 125V AC
Resistive Amps @ 208V AC
22 A
Sensor Location
Remote
Sensor Type
Hydraulic Capillary Bulb (Copper)
Standards
cULus; Hazardous Location Class I GroupC and D Class II Group E; NEMA 7 Div I
Temperature Sensitivity
+/-4°F
Key Features
Casting Tapped Top and Bottom for 3/4 in Conduit
Mounting Type
Surface Mount
UNSPSC
41112209
Country of Origin
USA (subject to change)
Product Description

These temperature controls are suitable for use in hazardous locations, like grain elevators, chemical plants, and mines. They control temperatures in Class I, Group D and Class II, Groups E, F, and G hazardous locations. Class I, Group D hazardous locations are areas where flammable gases or vapors may be present. Class II, Groups E, F, and G hazardous locations are areas where combustible dust may be present. These controls are compatible with single-stage systems. Single-stage systems have a single output level and allow the system to be either on or off. These controls have a capillary tube and sensor that monitor and regulate the temperature of the ambient air, a liquid, or a gas at a distance away from the control. The sensing element is not affected by changes in barometric pressure or cross-ambient conditions to ensure accurate temperature regulation.