Sorry, we’ve encountered a problem displaying product pricing. Please Refresh the page.

UL Class H & K5 Fuses

3 results found that include 117 Products

UL Class H and K5 fuses are used as replacement fuses for overcurrent protection in older HVAC installations. These fuses are dimensionally the same, so they can be interchanged to change from a current-limiting system using Class K fuses to a noncurrent-limiting system using Class H fuses. Class H fuses are used in low-interrupt applications while Class K fuses have a higher interrupting rating.Close

  • FILTER
  • SORT
Show All Selected Filters Show Less Selected Filters
  • Fast-Acting UL Class H & K5 Fuses, Nonindicating

    BUSSMANN

    Fast-Acting UL Class H & K5 Fuses, Nonindicating

    Multiple items available68

    N/A

  • About these products
    Fast-acting, nonindicating UL Class H and K5 fuses are for general purpose use in existing installations that require a high-sensitivity, fast-blow fuse. These fuses are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges, so they open within seconds of being exposed to overloads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Class H fuses are rated from 65A to 600A with an interrupting rating (IR) of 10kA for low-interrupt applications. Class K5 fuses are rated up to 60A with an interrupting rating (IR) of 50kA for higher interrupt applications and are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent. They're not labeled as current-limiting since they don't have a rejection feature.
    Fast-Acting UL Class H & K5 Fuses, Nonindicating
  • Time-Delay UL Class H Fuses, Nonindicating

    BUSSMANN

    Time-Delay UL Class H Fuses, Nonindicating

    Multiple items available19

    N/A

  • About these products
    Time-delay, nonindicating UL Class H fuses have a 10kA interrupting rating (IR) for general purpose use in existing installations where a small-interrupt, slow-blow fuse is needed. They're sometimes used in place of Class K5 fuses to downgrade from a current-limiting system. These renewable fuses have a fusible link that can be replaced after the fuse blows to allow reuse. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from equipment startups. They open to disconnect an electrical circuit when exposed to sustained loads and short circuits. These fuses have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.
    Time-Delay UL Class H Fuses, Nonindicating
  • UL Class H Replacement Fuse Links

    BUSSMANN

    UL Class H Replacement Fuse Links

    Multiple items available30

    N/A

  • About these products
    UL Class H replacement fuse links replace a blown link in Class H renewable fuses. These metal elements restore function to the fuse, allowing the fuse body to be reused rather than replaced.
    UL Class H Replacement Fuse Links