Sump Pump, 3/10HP, 1-1/2In NPT, 19ft Max, CI

ZOELLER

Price: $189.00 / each

Check Availability
Typically in Stock
4.5 Stars
4.5 of 5
  • Item # 2P547
  • Mfr. Model # M53
  • UNSPSC # 40151512
  • Catalog Page # 3670
  • Shipping Weight 22.45 lbs.
Country of Origin USACountry of Origin is subject to change.

Technical Specs

  • ItemSubmersible Sump Pump
  • HP3/10
  • Switch TypeVertical
  • Cord Length9 ft.
  • Voltage115
  • Amps9.6
  • Dia.10-3/32"
  • Discharge NPT1-1/2"
  • Height10-1/16"
  • Max. Head19 ft.
  • Max. Dia. Solids1/2"
  • GPM of Water @ 5 Ft. of Head43
  • GPM of Water @ 10 Ft. of Head34
  • GPM of Water @ 15 Ft. of Head19
  • Max. Temp.130 Degrees F
  • Off Point3"
  • On Point7-1/4"
  • Base MaterialPolypropylene
  • HousingCast Iron
  • Top MaterialCast Iron
  • Impeller MaterialPolypropylene
  • DutyContinuous
  • RPM1550
  • Thermal ProtectionYes
  • Shaft SealCarbon/Ceramic
  • Mechanical SealCRB/CMC
  • FeaturesFloat Operated, Corrosion-Resistant, Powder Coated Epoxy Finish, Stainless Steel Screws, Switch Arm, Guard and Handle, Watertight Neoprene Square Ring Between Motor and Pump Housing, Entire Unit Pressure Tested After Assembly

Compliance and Restrictions


This product contains a chemical that is regulated under California Proposition 65.

Warning: This product contains a chemical known to the State of California to cause cancer.

Warning: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.

Repair Parts

Displaying repair parts for model: M53

Alternate Products

Related Products


Rated 4.5 out of 5 by 12reviewers.
Rated 5 out of 5 by I maintain (2) mechanical sewer systems and this is only the third Zoeller pump I've bought over the past 15 years. And this one is a spare, so that aught to tell you what kind of service I've gotten over the years from thses pumps. Before going to the Zoeller pumps, I had used others but never got much more than a years service. October 9, 2013
Rated 5 out of 5 by As a Contractor and drainage expert serving the Bay Area for over 30 years we use these pumps on many of our projects! Excellent pump from Grainger! September 17, 2013
Rated 5 out of 5 Great pumps , I have owned a basement waterproofing company for 28 years. I just replaced a zoellar pump that I installed 25 1/2 years ago. Very dependable. July 19, 2013
Rated 4 out of 5 by i have had this sump for over 10yrs very durable, i had to put in a contact switch, other then that it's been working fine. ever since then it's been running smoother then when it was first installed. April 28, 2013
Rated 5 out of 5 by we use 16 of these in a daily operation and the work very well, last an expected amount of time and continue to replace old units with the same product as a good fix. March 27, 2013
Rated 5 out of 5 by Great Pump This is my preferred sump pump. It's heavy duty and long lasting. June 21, 2012
Rated 1 out of 5 by Failed in less than 2 years I had one in a new home purchased in 2008. It failed in less than 2 years, luckily I installed a battery backup. Replaced with a different brand. May 24, 2012
Rated 5 out of 5 by Does the job This pump is built to take on the loads and durable enough to that you can forget about the job that it is doing. April 5, 2012
2next>>
Product Reviews Disclaimer:
Grainger is neither responsible for, nor does it endorse, the content of any product review or statement posted. Any statements posted constitute the statements of the poster and are not the statements of Grainger. The statements posted by Grainger employees with the Grainger employee badge represent the views of such employees and are not the statements of Grainger. Grainger makes no representations as to the appropriateness, accuracy, completeness, correctness, currentness, suitability, or validity of any product review or statements posted, including those posted by employees with the Grainger employee badge, and is not liable for any losses, injuries or damages which may result from any such product review or statements. Use of any linked web site provided in a product review or post is at the user's own risk.

Product Q&A

(3 Questions : 6 Answers)

Ask your questions. Share your answers.

 
 
« Back
 
 
Do you just place this pump in the sump hole, pipe it up, and plug it in or are there settings you need to mess with like the float?

My mom has one which has been working find for 2 years and just started to cycle on/off. It keeps starting to lift the water but then it spits the water out a small hole on the side of the body. There is also a hole which had been drilled in the discharge pipe just as it thread into the pump. It also spits water out this hole.

HELP! My moms 95 and driving me crazy so any information would be appreciated.
1 year ago
by
Read all my Q&A
 
Please wait while more information about ThunderDog is loaded.
Additional information about ThunderDog could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Hello,
Sounds like a new pump, the hole in the pipe is reccomended. But if it is shooting out the side or the bottom, it could be plugged or worn out. There is no adjustment of the switch, just place it in the pit plumb it and plug it in. If when the pump shuts off the fluid flows back into the pit, you problem might be the Check Valve.. You can call us and ask to speak with tech support at 800-356-0783..

I hope this answers your question, thanks for using Grainger Ask & Answer!

Wadeh
1 year ago
by
Read all my Q&A
 
Please wait while more information about Wadeh is loaded.
Additional information about Wadeh could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
is the small hole on the side of the body a manufactory hole? their should not be a hole on the discharge piping. your boot @ the bottom of pump may need tighting up. hope this helps you. their should not be a hole on the side of the body.
11 months ago
by
Read all my Q&A
 
Please wait while more information about d4tay is loaded.
Additional information about d4tay could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
The only settings would be the level that you want to keep in you sump. I suspend my pumps in the sumps so they do not sit on the bottom of the sump tank where solids may accumulate. You can do that by the length of you discharge pipe.
6 months ago
by
Read all my Q&A
 
Please wait while more information about johndlcla is loaded.
Additional information about johndlcla could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
The holes are there so the pump won't get air locked. Suppose to be there. No settings to mess with. Set at factory.
8 months ago
by
Anonymous
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
I have a low volume requirement, perhaps 10 gpm, but needs to be auto on/off. I have a 12" x 12" sump.
2 months ago
by
Read all my Q&A
 
Please wait while more information about TireShredder is loaded.
Additional information about TireShredder could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
The turn on point for this unit will require the water depth in your pit to reach approximately 7 ¼”. If your water depth does not reach that level, please contact us at 1-800-GRAINGER for other options.

Thank you for using Grainger Ask and Answer.
2 months ago
by
Read all my Q&A
 
Please wait while more information about ChrisO is loaded.
Additional information about ChrisO could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
3 weeks, 6 days ago
by
Read all my Q&A
 
Please wait while more information about scottso is loaded.
Additional information about scottso could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Grainger has contacted the product supplier and has been advised by them of the following:

If the pump is placed directly on the base of the pit there will be approximately 3” of water left when the pump turns off.

Thank you for using Grainger Ask and Answer.
3 weeks, 4 days ago
by
Read all my Q&A
 
Please wait while more information about ChrisO is loaded.
Additional information about ChrisO could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
1 of 1
1 of 1

Ask and Answer Disclaimer:
Grainger is neither responsible for, not does it endorse, the content of any statement posted. Any statements posted constitute the statements of the poster and are not the statements of Grainger.

The statements posted by Grainger employees with the Grainger employee badge represent the views of such employees and are not the statements of Grainger. Grainger makes no representations as to the appropriateness, accuracy, completeness, correctness, currentness, suitability, or validity of any statements posted, including statements posted by employees with the Grainger employee badge, and is not liable for any losses, injuries or damages which may result from any such statements.

Use of any linked web site provided in a post is at the user's own risk. This site should not replace the use by you of any technical product manual or other professional resource or adviser available to you.

The source for the answers given by Grainger in Ask and Answer are based on the information provided with the question, which may not be complete or may not apply to other situations, and based on product literature and informational materials, the content of which is provided by Grainger's product suppliers. Grainger disclaims liability for any information it provides in Ask and Answer which later may be alleged or determined by a court of law to be inaccurate or incorrect.

The answers given by Grainger in Ask and Answer are not intended to replace or supplement any professional, engineering or other consultation services available to its product users. Always read, understand, and follow the product information and instructions provided by the manufacturer. same on category AAA as well