Emerson Model K55HXPRR-5274
1/4 HP
Pt No. 024-25119-000
Volt 208-230
H2 50/60
AMP 1.6 PH 1
R.P.M. 850
Frame 48Y
Thank you,
Ron
3 days ago
by
Read all my Q&A
 
Please wait while more information about ChuckRoast is loaded.
Additional information about ChuckRoast could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too
3 weeks, 3 days ago
by
Read all my Q&A
 
Please wait while more information about huff7548 is loaded.
Additional information about huff7548 could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Check out page 4550 in the grainger catalog.
2 weeks, 5 days ago
by
Read all my Q&A
 
Please wait while more information about FranklinC is loaded.
Additional information about FranklinC could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
What potential damage could be caused by replacing 370VAC with a 440VAC?
1 month, 1 week ago
by
Read all my Q&A
 
Please wait while more information about DelsJeep is loaded.
Additional information about DelsJeep could not be loaded.
+2points
2out of 2found this question helpful.
Was this helpful?helpful2unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Yes you can use the 440V for replace a 370V, as long are the same MFD. there is not any problem and is safe, but never use the 370V for replace a 440V.
1 month ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Answer: 
Yes. As long as the MFD (microfarad) are the same. You can take a higher rated VAC (voltage alternating current) capacitor and use it in a lower application.
2 weeks, 5 days ago
by
Read all my Q&A
 
Please wait while more information about FranklinC is loaded.
Additional information about FranklinC could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
1 answer

Heat and air

Looking for an air conditioner and heater combined for a 10x20
storage room. windows not measured yet, but no longer than 20"
(approx). Anyway measurement or not, I still need to know if you sell them
1 month, 1 week ago
by
Read all my Q&A
 
Please wait while more information about Sookie is loaded.
Additional information about Sookie could not be loaded.
-1point
0out of 1found this question helpful.
Was this helpful?helpful0unhelpful1
1 Person needs an answerI have this question too

Answers

Answer: 
I need more information, but you probably are looking for a 9000btu window unit with heat, its AC and heat in one unit. Call Grainger they have this unit. They will also may ask you what volt you have there 115V, 208V, 230V.
1 month ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
1 month, 2 weeks ago
by
Read all my Q&A
 
Please wait while more information about TWest is loaded.
Additional information about TWest could not be loaded.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
On your condenser unit, it's the one out side, if you open the electric cover, is in the corner of your unit. Inside there is printed your electrical Blueprint, look there it will show you where are the contacts points.
1 month ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
model #5KCP39LF Y534AS
HP 1/4
V208-230
CPN HC39GE242A
RPM 825
A 1.20
UYFA0162032
CAP7.50/370V
HZ60
PH1
2 months, 2 weeks ago
by
Read all my Q&A
 
Please wait while more information about Tuan is loaded.
Additional information about Tuan could not be loaded.
+1point
1out of 1found this question helpful.
Was this helpful?helpful1unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Our 4M226 meets your specifications and do not forget the required capacitor 2MDV4.

Thank you for using Grainger Ask & Answer.
2 months, 2 weeks ago
by
Read all my Q&A
 
Please wait while more information about ThomasP is loaded.
Additional information about ThomasP could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
3 months ago
by
Read all my Q&A
 
Please wait while more information about clogged is loaded.
Additional information about clogged could not be loaded.
+2points
2out of 2found this question helpful.
Was this helpful?helpful2unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
You need the Gun, Grainger Item # 1GDL7 and the Cartridges, Grainger Item # 1GDL8. Good product, I'm using it for 5 years, you only buy the guy one time, then just the cartridges, they have CO2 with high pressure to blow the clog away, if the pan is dry put little bit water first, that help to push the clog. it came with a short hose and adaptors.
3 months ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0

Answer: 
It's called bleach and a vacuum. Your welcome.
2 weeks, 5 days ago
by
Read all my Q&A
 
Please wait while more information about FranklinC is loaded.
Additional information about FranklinC could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
My vent is too long and creates back pressure so vent clogs with lint. Looking for a booster fan that mounts in line to keep air flow moving
3 months, 3 weeks ago
by
Read all my Q&A
 
Please wait while more information about Airflow is loaded.
Additional information about Airflow could not be loaded.
+1point
1out of 1found this question helpful.
Was this helpful?helpful1unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Look Grainger items # 15W791 and # 15W792.
3 months, 3 weeks ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
Has staff answer
 
2 answers

do you carry any tempster hvac parts

5 months, 1 week ago
by
Read all my Q&A
 
Please wait while more information about skiddro is loaded.
Additional information about skiddro could not be loaded.
+1point
1out of 1found this question helpful.
Was this helpful?helpful1unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
That does not appear to be a supplier we carry but if you have part numbers we can see if we can cross it to something we do carry. Please call 1-800-Grainger and any agent can assist you with this.

Thank you for using Grainger.com Ask & Answer.
4 months, 3 weeks ago
by
Read all my Q&A
 
Please wait while more information about AngieO is loaded.
Additional information about AngieO could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

Answer: 
No. You may have to rephrase your question.
2 weeks, 5 days ago
by
Read all my Q&A
 
Please wait while more information about FranklinC is loaded.
Additional information about FranklinC could not be loaded.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
I need a waist high Thermal Jacket or coat for use while working inside inside Deep Freezer. Do you carry this item.
6 months ago
by
Read all my Q&A
 
Please wait while more information about Chitra is loaded.
Additional information about Chitra could not be loaded.
+1point
1out of 1found this question helpful.
Was this helpful?helpful1unhelpful0
1 Person needs an answerI have this question too

Answers

Answer: 
Look catalog Grainger page #2321, if you don't have the catalog, just click on "catalog 405" at the top of the Grainger webpage.
6 months ago
by
Read all my Q&A
 
Please wait while more information about gooddude is loaded.
Additional information about gooddude could not be loaded.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0